The project was presented 14/10-2011 and broadcasted on the Ukrainian television. See the broadcast beneath.
The aim of the project is to clean the flue gas from the coal fired boiler. In total it is more than 80,000 Am3/h at a temperature up to 200 C⁰ .
Because the filter is using down-flow filtration the loading on the Nomex filterbags are as high as 1,9 Am3/m2*min.
The project was commissioned 27/1-2012 and after the commissioning the rest dust amount was measured and it was as low as 10 mg/Nm3 - which is much lower than the local and the international requirements.
techNaero filter R4060-10
Installation before commissioning
Installation after commissioning
restdust <10mg/Nm3
Presentation of the project on Ukranian TV.
To activate the subtitles please press the CC button in the utility toolbar in the embedded Youtube video.